KAJIAN APLIKASI KOAGULAN PAC DAN KOAGULAN ACH DI IPA PEJOMPONGAN II

Authors

  • Kristianti Utomo Program Studi Teknik Lingkungan, Sekolah Tinggi Sapta Taruna Author
  • Benny Kusdinar Program Studi Teknik Lingkungan, Sekolah Tinggi Sapta Taruna Author
  • Apriliana Dewaningrum Program Studi Teknik Lingkungan, Sekolah Tinggi Sapta Taruna Author

Keywords:

ACH, Coagulants, Organic Substance Removal Efficiency, PAC, Turbidity Removal Efficiency

Abstract

IPA Pejompongan I and IPA Pejompongan II, PT PALYJA used ACH as the main coagulant in 2016. However, to obtain an efficient coagulant, a study was conducted to find alternative coagulants. The alternative coagulant is PAC. In this case, data analysis of the application of PAC coagulant compared with ACH coagulant in IPA Pejompongan II related to variations in turbidity was carried out in order to explain the effectiveness between the use of PAC and ACH coagulants. Data on the quality of raw water, production water, and the use of coagulant doses of PAC and ACH were analyzed using the statistical method Independent Samples T Test resulted for the turbidity parameter with the maximum dose and the average dose (mode) obtained a p value of 0.000 while the minimum dose obtained a value of 0.000 p value of 0.071 using an alpha value of 5% (0.005), then for the maximum dose and the average dose (mode) the p value is smaller, while for the minimum dose the p value is greater. For the pH parameter with the maximum dose, the p value is 0.017 and with the average dose (mode) and the minimum, the p value is 0.000 using an alpha value of 5% (0.005), then for the maximum dose, the average (mode) is and the minimum p value is smaller. In addition to analyzing using statistical methods, the data is also analyzed through the calculation of the efficiency of removal of turbidity and efficiency of removal of organic matter.

Downloads

Download data is not yet available.

References

Peraturan Menteri Kesehatan Persyaratan Kualitas Air Minum No. 492 492/MENKES/PER/IV/2010 tentang Persyaratan Kualitas Air Minum

Peraturan Pemerintah Republik Indonesia Nomor 82 Tahun 2001 Tentang Pengelolaan Kualitas Air Dan Pengendalian Pencemaran Air

PAM JAYA.co.id (2017) “2030, DKI Terlayani Air Bersih”. http://pamjaya.co.id/id/others/news/2030_dki_is_served_with_clean_water-56

Yuliati, Suci. (2006). “Proses Koagulasi –Flokulasi Pada Pengolahan Tersier Limbah Cair PT. Capsugel Indonesia”. Skripsi Sarjana Teknologi Pertanian. Departemen Teknologi Industri Pertanian.Fakultas Teknologi Pertanian, Institut Pertanian Bogor

Damanhuri, Enri, 1989, Pendekatan Sistem Dalam Pengendalian dan Pengoperasian Sistem Jaringan Distribusi Air Minum, Bandung, Jurusan Teknik Lingkungan FTSP-ITB.

Departemen PU. DJCK. 2007. Nomor 18/PRT/M/2007. Tanggal 06 Juni 2007. tentang Penyelenggaraan Pengembangan Sistem Penyediaan Air Minum.

Direktorat Jendral Cipta karya, 05. Pengembangan Air Minum 17-09 2007. Ida Dhaliawati. 2013. Modul Pengolahan Air Minum. Jakarta.

PDAM Kota Surakarta. Profil. 2017. Kabupaten Jawa tengah.

PP RI Nomor 82 tahun 2001 tentang Persyaratan Kualitas Air Baku.

PP RI No. 16 Tahun 2005 tentang Sistem Penyediaan Air Minum

PerMenKes RI Nomor 492/Menkes/Per/IV/2010 tentang Persyaratan Kualitas Air Minum.

SNI 6773:2008 tentang Spesifikasi Unit Paket Instalasi Pengolahan Air

SNI 6774:2008 tentang Tata Cara Perencanaan Unit Paket Instalasi Pengolahan Air

Sutrisno, Totok dkk. 2004. Teknologi Penyediaan Air Bersih. Jakarta: Rineka Cipta.

UU RI No. 7 tahun 2004 tentang Sumber Daya Air.

Downloads

Published

2022-09-30

How to Cite

KAJIAN APLIKASI KOAGULAN PAC DAN KOAGULAN ACH DI IPA PEJOMPONGAN II. (2022). Jurnal Green Construction, 2(Kesatu), 38-48. https://ojs.sttpu.ac.id/index.php/greenconstruction/article/view/29

Most read articles by the same author(s)